Calcium

Supply #T157 Red/Yellow SST 8mL

Test Code: 303

CPT Code(s): 82310

Includes: Calcium

Methodology: Spectrophotometry (SP)

Clinical Significance: Serum calcium is involved in the regulation of neuromuscular and enzyme activity, bone metabolism and blood coagulation. Calcium blood levels are controlled by a complex interaction of parathyroid hormone, vitamin D, calcitonin and adrenal cortical steroids. Calcium measurements are useful in the diagnosis of parathyroid disease, some bone disorders and chronic renal disease. A low level of calcium may result in tetany.

Alternative Name(s): CA, CA+, CAL, Calcium by Spectrophotometry


 

Collection Guide

Supply: #T157 Red/Yellow SST 8mL

Preferred Specimen: Serum

Preferred Volume: 1mL

Transport Container: Serum Separator Tube (SST)

Transport Temperature: Room Temperature

Specimen Stability: Room Temperature: 7 days

Rejection Criteria: 

  • Hemolysis
    • What are hemolyzed specimens?
      • Hemolysis occurs when the red cells are damaged during sample collection causing them to rupture.  Hemolyzed serum or plasma is pale pink to red rather than the normal clear straw or pale-yellow color.
    • What causes a specimen to be hemolyzed?
      • Mixing tubes too vigorously
      • Placing tubes in the refrigerator without allowing 30 minutes at room temperature for complete clotting
      • Exposure to heat or in a refrigerator that is too cold
      • Using a needle with too small of a bore necessary for the venipuncture
      • Using too large a tube when using a butterfly needle
      • Not allowing sufficient time for alcohol to dry on puncture site
      • Leaving the tourniquet on for longer than one minute
    • How can hemolyzed specimens be prevented?
      • For routine collections, use a 20–22-gauge needle
      • Do not remove the needle from the vein with the vacuum tube engaged
      • Do not collect a specimen in a hematoma
      • Do not centrifuge the specimen for a prolonged period of time
      • Draw the sample gently and evenly
  • Specimens exceeding stability
  • Specimens other than serum
  • Unlabeled or improperly labeled specimens

For additional supply or collection device information, please contact DLO's Customer Service at (800) 891-2917, option 2.

The CPT codes provided are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the Payor being billed.

Additional names
CA
CA+
CAL
Calcium by Spectrophotometry
CPT Code(s)
82310
Test Code
303