C-reactive Protein

Supply #T157 Red/Yellow SST 8mL

Test Code: 4420

CPT Code(s): 86140

Methodology: Nephelometry

Limitations: Oral contraceptives, IUDs, pregnancy, and menstruation may raise CRP levels. Levels are lowest during ovulation.

Clinical Significance: Increased CRP levels are found in inflammatory conditions including: bacterial infection, rheumatic fever, active arthritis, myocardial infarction, malignancies and in the post-operative state. This test cannot detect the relatively small elevations of CRP that are associated with increased cardiovascular risk.

Alternative Name(s): CRP


 

Collection Guide

Supply: #T157 Red/Yellow SST 8mL

Preferred Specimen: Serum

Preferred Volume: 1mL

Transport Container: Serum Separator Tube (SST)

Transport Temperature: Room Temperature

Specimen Stability: Room Temperature: 7 days

Rejection Criteria: 

  • Hemolysis
    • What are hemolyzed specimens?
      • Hemolysis occurs when the red cells are damaged during sample collection causing them to rupture.  Hemolyzed serum or plasma is pale pink to red rather than the normal clear straw or pale-yellow color.
    • What causes a specimen to be hemolyzed?
      • Mixing tubes too vigorously
      • Placing tubes in the refrigerator without allowing 30 minutes at room temperature for complete clotting
      • Exposure to heat or in a refrigerator that is too cold
      • Using a needle with too small of a bore necessary for the venipuncture
      • Using too large a tube when using a butterfly needle
      • Not allowing sufficient time for alcohol to dry on puncture site
      • Leaving the tourniquet on for longer than one minute
    • How can hemolyzed specimens be prevented?
      • For routine collections, use a 20–22-gauge needle
      • Do not remove the needle from the vein with the vacuum tube engaged
      • Do not collect a specimen in a hematoma
      • Do not centrifuge the specimen for a prolonged period of time
      • Draw the sample gently and evenly
  • Specimens exceeding stability
  • Specimens other than serum
  • Unlabeled or improperly labeled specimens

For additional supply or collection device information, please contact DLO's Customer Service at (800) 891-2917, option 2.

The CPT codes provided are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the Payor being billed.

Additional names
CRP
CPT Code(s)
86140
Test Code
4420