Test Code: 873
CPT Code(s): 84403
Supply: #T157 Red/Yellow SST 8mL
Methodology: Immunoassay
Limitations: Immunoassay does not provide sufficient sensitivity in detecting low concentrations among non-adults and women.
Clinical Significance: Testosterone circulates almost entirely bound to transport proteins: Normally less than 1-2% is free. The principal transport protein for testosterone is known as sex hormone binding globulin (SHBG) or testosterone-estradiol binding globulin (TeBG). Testosterone measurements are used to assess erectile dysfunction, infertility, gynecomastia, and osteoporosis and to assess hormone replacement therapy.
Additional names: N/A
Supply: #T157 Red/Yellow SST 8mL
Preferred Specimen: Serum
Preferred Volume: 1mL
Transport Container: Red Top Tube (NO GEL)
Transport Temperature: Room Temperature
Specimen Stability: Room Temperature: 72 hours
Special Instructions: This assay should be performed on adult (> or = 18 years) males. Immunoassay does not provide sufficient sensitivity in detecting low concentrations among non-adults and women.
Reject due:
- Contact our Client Services department for specific details
- Hemolysis
- What are hemolyzed specimens?
- Hemolysis occurs when the red cells are damaged during sample collection causing them to rupture. Hemolyzed serum or plasma is pale pink to red rather than the normal clear straw or pale-yellow color.
- What causes a specimen to be hemolyzed?
- Mixing tubes too vigorously
- Placing tubes in the refrigerator without allowing 30 minutes at room temperature for complete clotting
- Exposure to heat or in a refrigerator that is too cold
- Using a needle with too small of a bore necessary for the venipuncture
- Using too large a tube when using a butterfly needle
- Not allowing sufficient time for alcohol to dry on puncture site
- Leaving the tourniquet on for longer than one minute
- How can hemolyzed specimens be prevented?
- For routine collections, use a 20–22-gauge needle
- Do not remove the needle from the vein with the vacuum tube engaged
- Do not collect a specimen in a hematoma
- Do not centrifuge the specimen for a prolonged period of time
- Draw the sample gently and evenly
- What are hemolyzed specimens?
- Specimens exceeding stability
- Specimens other than serum
- Unlabeled or improperly labeled specimens
For additional supply or collection information, please contact DLO's Customer Service at (800) 891-2917, option 2.
The CPT codes provided are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed.