TSH with Reflex to FT4

Supply #T157 Red/Yellow SST 8mL

Test Code:  36127 - TSH with Reflex to FT4

CPT Code(s):  84443

Supply: #T157 Red/Yellow SST 8mL

Includes: 
Test Code 36127: For patients 1 year of age or older, Free T4 will be performed at an additional charge (CPT code(s): 84439) when TSH result exceeds age/gender specific reference range.

Methodology: Immunoassay

Clinical Significance: 
Test Codes 899 & 36127: For differential diagnosis of primary, secondary, and tertiary hypothyroidism. Also useful in screening for hyperthyroidism. This assay allows adjustment of exogenous thyroxine dosage in hypothyroid patients and in patients on suppressive thyroxine therapy for thyroid neoplasia.

Additional names: 
Test Code 36127: Thyrotropin; 3rd Generation TSH; Thyroid Function; Thrrotropin w/ reflex to FT4; TSH Ultrasensitive; TSH w/FT4 Reflex; TSH w/RFX; Ultra TSH w/Rfx to Free T4

 


 

Collection Guide

Supply: #T157 Red/Yellow SST 8mL

Preferred Specimen: Serum

Preferred Volume: 1mL

Transport Container: Serum Separator Tube (SST)

Transport Temperature: Room Temperature

Specimen Stability: Room Temperature: 7 Days

Reject due: 

  • Hemolysis
    • What are hemolyzed specimens?
      • Hemolysis occurs when the red cells are damaged during sample collection causing them to rupture.  Hemolyzed serum or plasma is pale pink to red rather than the normal clear straw or pale-yellow color.
    • What causes a specimen to be hemolyzed?
      • Mixing tubes too vigorously
      • Placing tubes in the refrigerator without allowing 30 minutes at room temperature for complete clotting
      • Exposure to heat or in a refrigerator that is too cold
      • Using a needle with too small of a bore necessary for the venipuncture
      • Using too large a tube when using a butterfly needle
      • Not allowing sufficient time for alcohol to dry on puncture site
      • Leaving the tourniquet on for longer than one minute
    • How can hemolyzed specimens be prevented?
      • For routine collections, use a 20–22-gauge needle
      • Do not remove the needle from the vein with the vacuum tube engaged
      • Do not collect a specimen in a hematoma
      • Do not centrifuge the specimen for a prolonged period of time
      • Draw the sample gently and evenly
  • Plasma
  • Specimens exceeding stability
  • Specimens other than serum
  • Unlabeled or improperly labeled specimens

For additional supply or collection information, please contact DLO's Customer Service at (800) 891-2917, option 2.

The CPT codes provided are based on AMA guidelines and are for informational purposes only. CPT coding is the sole responsibility of the billing party. Please direct any questions regarding coding to the payor being billed.

Additional names
Test Code 899; Highly Sensitive TSH; TSH
Highly Sensitive; 9/9/96-CHGD Field 25-Bac; 2nd Generation TSH; Thyrotropin; 3rd Generation TSH; Hypersensitive TSH; PEDS TSH; Supersensitive TSH; Thyroid Stimulatin Hormone; TSH3; TSH Highly Sensitive; TSH Ultra-Sensitive; TSH
Delta
Single Specimen; TSH
Psychiatric
Single Specimen
CPT Code(s)
84443
Test Code
36127